Specifications
|
Indoor Unit |
RAS-16E2KV2G-A |
||
|
Outdoor Unit |
RAS-16E2AVG-A |
||
|
Cooling Capacity – Rated |
CO |
kW |
4.20 |
|
Cooling Capacity – Range |
CO |
kW |
1.30 – 5.00 |
|
Power input [rated (min – max)] |
CO |
kW |
1.30 (0.32 – 1.90) |
|
Operating current [rated (min – max)] |
CO |
A |
6.55 (1.91 – 9.10) |
|
AEER |
CO |
|
3.24 |
|
Heating Capacity – Rated |
RC |
kW |
5.40 |
|
Heating Capacity – Range |
RC |
kW |
1.30 – 6.00 |
|
Power input [rated (min – max)] |
RC |
kW |
1.43 (0.25 – 1.80) |
|
Operating current [rated (min – max)] |
RC |
A |
7.05 (1.50 – 8.70) |
|
ACOP |
RC |
|
3.53 |
|
Indoor Unit |
|||
|
Airflow Volume (High/Mid/Low) |
CO |
m³/hr |
790/540/330 |
|
Mositure removal |
|
l/hr |
2.80 |
|
Dimension (WxLxH) |
|
mm |
293 x 798 x 230 |
|
Net Weight |
|
kg |
10 |
|
Sound Power at Cooling Operation (high) |
CO |
dB |
62 |
|
Outdoor Unit |
|||
|
Dimension (WxLxH) |
|
mm |
290 x 780 x 550 |
|
Net Weight |
|
kg |
30 |
|
Cooling Operating range (Outside) |
CO |
◦C |
-10 ~ 46 |
|
Heating Operating range |
RC |
◦C |
-15 ~ 24 |
|
Sound Power at Cooling Operation (high) |
CO |
dB |
67 |
|
Pipe Size |
|||
|
Liquid Side |
|
(mm) |
6.35 |
|
Gas Side |
|
(mm) |
12.7 |
|
Maximum Piping Length |
|
(m) |
20 |
|
Maximum Piping Height difference |
|
(m) |
12 |
|
Chargeless Length |
|
(m) |
15 |
|
Compressor type |
|
|
Twin Rotary |
|
Power Supply |
|
V/ph/Hz |
220-240V/1Ph/50Hz |